Construction assembly A1463

Lignum ID-№
A1463
Catalog number
A.2.03.--
Source of construction assembly
Lignatur X09_07_08_lke_silence12_trocken_45kgschuettung_69db_47db, Year 2014
Base structure
Hollow box element
Paneling
Without covering
Reference fire protection
VKF Brandschutzanwendung Nr. 15421
Construction height
288 mm
Weight
176 kg/m2
U-value
≈ 0.321 W/m2K
GWP
9.35 kg CO2-eq/m2
Type sound insulation
Measurement
Ceiling consisting of a basic construction of hollow box element, without sheathing, without ceiling covering, with dampening in supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 15 MN/m³ and with dry screed.
Values of airborne sound insulation
Rw 69 dB
C -4 dB
C50-3150 -10 dB
Values of footfall sound insulation
Ln,w 47 dB
CI 1 dB
CI50-2500 5 dB

Graphic

On-lying material: SWISSSPAN P2 ECO Verlegeplatten
Impact sound insulation: Akustic EP2
Dampening on Supporting structure: Dampening gravel ≤ 1400 kg/m³
Sub-floor: Lignatur box-element sheathing above
Supporting structure: Lignatur box-element LKE silence12
Dampening in supporting structure: Damper and limestone granules LKE silence12
Lower skin layer 1: Lignatur box-element sheathing below

Assembly

Comment Lignatur_X09_07_08_lke_silence12_trocken_45kgschuettung_69db_47db

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material SWISSSPAN P2 ECO Verlegeplatten Label swiss wood, Swiss Krono Group - - - 07.015 91.145
Impact sound insulation Akustic EP2 Isover 2.1 kg/m2 - - 10.001.01 91.173
Dampening on Supporting structure Dampening gravel ≤ 1400 kg/m³ Fermacell, Zisola 42 kg/m2 - - 03.011 91.062
Sub-floor Lignatur box-element sheathing above Lignatur 15.2 kg/m2 - - 07.011.01 91.052
Supporting structure Lignatur box-element LKE silence12 Lignatur 4.9 kg/m2 - -
Dampening in supporting structure Damper and limestone granules LKE silence12 Lignatur 97.3 kg/m2 - - 03.011 91.062
Lower skin layer 1 Lignatur box-element sheathing below Lignatur 15.2 kg/m2 - - 07.011.01 91.052

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
26816
UBP'21/m2
A1-A3 + C1-C4
 
┣
Environmental impact points from production (UBP_pro)
19049
UBP'21/m2
A1-A3
 
┗
Environmental impact points from disposal (UBP_dis)
7755
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
231.05
kWh oil-eq/m2
A1-A3 + C1-C4
 
┣
Primary energy from production (PE_pro)
220.08
kWh oil-eq/m2
A1-A3
 
┃
┣
Primary energy production, energetically consumed (PE_E_pro)
63.62
kWh oil-eq/m2
A1-A3
 
┃
┗
Primary energy production, materially bound (PE_M_pro)
156.46
kWh oil-eq/m2
A1-A3
 
┗
Primary energy from disposal (PE_dis)
10.82
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
186.02
kWh oil-eq/m2
A1-A3 + C1-C4
 
┣
Renewable primary energy from production (PE_RT_pro)
185.69
kWh oil-eq/m2
A1-A3
 
┃
┣
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
29.11
kWh oil-eq/m2
A1-A3
 
┃
┗
Renewable primary energy from production, materially bound (PE_RM_pro)
156.46
kWh oil-eq/m2
A1-A3
 
┗
Renewable primary energy from disposal (PE_RT_dis)
0.52
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
44.84
kWh oil-eq/m2
A1-A3 + C1-C4
 
┣
Primary energy not renewable from manufacturing (PE_NRT_pro)
34.52
kWh oil-eq/m2
A1-A3
 
┃
┣
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
34.52
kWh oil-eq/m2
A1-A3
 
┃
┗
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0.00
kWh oil-eq/m2
A1-A3
 
┗
Primary energy not renewable from disposal (PE_NRT_dis)
10.31
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
9.35
kg CO2/m2
A1-A3 + C1-C4
 
┣
Greenhouse gas emissions from manufacturing (GWP_pro)
6.29
kg CO2/m2
A1-A3
 
┗
Greenhouse gas emissions from waste disposal (GWP_dis)
3.06
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
50.24
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
13.70
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)